PHISICAL PICTURE |
|
Features: |
|||||
![]()
|
|
◆ AC 100-240V Wide-range Input |
|||||
|
◆ Small Size |
||||||
|
◆ Efficiency up to 75% |
||||||
|
◆ 120%PeakLoad Capability |
||||||
|
◆ Active Power Factor Correction (PFC) |
||||||
|
◆ High lightning surge up to 6kV for CM & DM |
||||||
|
◆ DC Input from 88 to 375V |
||||||
|
◆ Negligible low Inrush Current Surge |
||||||
|
◆ Short-term Operation Down to 60Vac and up to 300Vac |
||||||
|
◆ Full Power Between-25℃and +85℃ |
||||||
|
◆ Three years Warranty |
||||||
|
|
||||||
|
|
||||||
|
|
|
|||||
GENERAL DESCRIPTION |
|
SHORT-FORM DATA |
|||||
The model is widely used in communication equipment such as Ethernet, switchboards, routers, LANs, MANs, etc.. The most outstanding features of this dimension are the high efficiency and the small size, which are achieved by using an advanced controller and further novel design details. With short-term peak power capability of 110% and built-in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used. High immunity to transient and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. High lightning surge makes usage well in telecommunication & power electric industry. The integrated output power manager and a wide range input voltage design make usage simple. Small package makes installation more simple and suitable for nearly every telecom device. |
|
Input Voltage |
AC 100-240V |
+10/-15% |
|||
|
Mains Frequency |
50-60Hz |
±6% |
||||
|
Input AC Current |
0.50/0.25A |
@110/230Vac |
||||
|
Power Factor |
-- |
@110/230Vac |
||||
|
Inrush Current |
40A |
@110/230Vac |
||||
|
Output Voltage |
12Vdc |
|
||||
|
Adjustment range |
11.85~12.15Vdc |
|
||||
|
Output Current |
2.5A |
continuous |
||||
|
2.75~3.15A |
for typ. 4s |
|||||
|
Output Power |
25W |
continuous |
||||
|
|
|
|||||
|
Output Ripple |
< 50mV < 100mV |
@Io<2.1A& Io>0.15A @Io>0.2A |
||||
|
Efficiency |
75% |
@110/230Vac |
||||
|
Losses |
≤ 4W |
@110/230Vac |
||||
|
Load Regulation |
±1% |
|
||||
|
Line Regulation |
±1% |
|
||||
|
Hold-up time |
typ. 20ms |
@110/230Vac |
||||
|
Work temperature |
-20~+80℃ |
operation |
||||
|
Dimensions |
84.5*41.5*35.0mm |
L×W×H |
||||
|
|
|
|
|
|||
Mechanical Specification |
|
|
|||||
|
|
|
|
|
|
|
|
|
Unit: mm |
|
|||||
|
Input Connector |
||||||
|
Pin1 |
Neutral |
|||||
|
Pin2 |
NC |
|||||
|
Pin3 |
Line |
|||||
|
CON1: |
||||||
|
JST B3P-VH or equivalent |
||||||
|
|
||||||
|
Output Connector |
||||||
|
Pin1 |
Vo+ |
|||||
|
Pin2 |
Vo+ |
|||||
|
Pin3 |
Vo- |
|||||
|
Pin4 |
Vo- |
|||||
|
CON2: |
||||||
|
JST B4P-VH or equivalent |
||||||
|
|
|
|||||
|
|
|
|
|
|
|
|
Notes: |
|
|
|
|
|
|
|
1. All dimensions in mm. |
|
3. Weight :250gapprox. |
|||||
2. Tolerance .xx = ±0.50; .xxx = ±0.25 |
|
|